What is the difference between green and blue SC connectors?

Jul 10, 2025

here's a deeper technical breakdown of the differences between blue (UPC) and green (APC) SC fiber optic connectors, including physical, performance, and application-specific distinctions.

 

1. Physical Structure of the Connector

Aspect UPC (Blue SC) APC (Green SC)
Ferrule Material Typically ceramic (zirconia) Same
Polishing Type Ultra Physical Contact Angled Physical Contact
Polish Angle 0° (flat with a dome shape) 8° angle to reduce reflections
Endface Geometry Domed surface with very fine polish Angled endface for minimal back reflection
Connector Color Blue Green

 

2. Optical Performance Parameters

Parameter UPC (Blue) APC (Green)
Insertion Loss ~0.2–0.3 dB ~0.3–0.4 dB
Return Loss (Back Reflection) ≥ -50 dB (typical) ≥ -60 dB to -70 dB
Reflection Tolerance Moderate Very low (ideal for high-sensitivity systems)
Repeatability Good Excellent
Durability High (can withstand >500 matings) Same or better

 

3. Application Differences

Use Case Use UPC (Blue SC) Use APC (Green SC)
Ethernet, LAN, general digital comms ✅ Yes 🚫 Not required
Data centers, short single-mode runs ✅ Yes Optional
FTTx (Fiber to the Home/Building/Node) 🚫 Not ideal ✅ Strongly preferred
RF over fiber (analog TV, CATV, satellite) 🚫 Causes interference ✅ Required
PON networks (Passive Optical Network) 🚫 Causes high back reflection ✅ Standard
Test equipment ✅ Sometimes ✅ Sometimes (depending on test)

 

4. Compatibility Notes

Physical Keying: SC connectors are keyed (notched) to prevent inserting APC into UPC ports and vice versa.

Signal Integrity: Mismatched connectors (e.g., APC-to-UPC) lead to air gaps, high return loss, and performance degradation.

Fiber Types: Both UPC and APC are used primarily with single-mode fiber (SMF), but UPC can also be used with multimode (MMF).

 

5. Practical Selection Advice

Environment Recommendation
Short indoor runs (server rooms, labs) Use UPC (Blue) - simple, cost-effective
Long outdoor runs, PON systems, FTTH Use APC (Green) - better signal quality, less reflection
Audio/Video over fiber APC preferred to avoid signal distortion
Fiber testing or precise instrumentation Match connector polish - use UPC or APC as required

 

6. Visual Identification Tip

Feature UPC APC
Color Blue Green
Endface (if visible) Flat dome Angled cut
Labeling Sometimes marked "UPC" Often labeled "APC" or has 8° symbol